Helium • Regulator Installation
Insert the threaded end of the regulator into the side opening of the tank and hand-
Make sure your helium tank is secure and remove the cap from the helium tank.
tighten the connection. DO NOT use a wrench to tighten as it will cause damage to the O-ring seal.
Turn on the helium tank. If a leaking sound occurs, turn off the tank, release pressure from the regulator by depressing the push valve, and retighten the regulator again.
Check the gauge for pressure and tank levels. Re-order helium when the gauge registers in the yellow zone.
NOTE: It is not necessary to turn off your tank after each use, but be sure to turn off the tank at the end of each day.